Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 218
Filtrar
1.
J Clin Med ; 13(7)2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38610900

RESUMO

Background: Achondroplasia is a rare genetic disease, yet the most common form of dwarfism, characterized by limb shortening and disproportionate short stature along with musculoskeletal changes, such as postural deviations. Although postural changes in the spine in children with achondroplasia have been well investigated, little is known about the association of achondroplasia with spinal movements/mobility. Methods: This preliminary study aims to explore the association of achondroplasia with spinal mobility in children with achondroplasia compared to age- and sex-matched healthy individuals. Spinal posture and mobility were assessed using a radiation-free back scan, the Idiag M360 (Idiag, Fehraltorf, Switzerland). Between-group differences were determined using a two-way analysis of variance. Results: Children with achondroplasia had smaller thoracic lateral flexion [difference between groups (Δ) = 20.4°, 95% CI 0.1°-40.6°, p = 0.04], lumbar flexion (Δ = 17.4°, 95% CI 5.5°-29.4°, p = 0.006), lumbar extension (Δ = 14.2°, 95% CI 5.7°-22.8°, p = 0.002) and lumbar lateral flexion (Δ = 19.6°, 95% CI 10.7°-28.4°, p < 0.001) than age- and sex-matched healthy individuals, except for thoracic extension (Δ = 16.5°, 95% CI 4.4°-28.7°, p = 0.009) which was greater in children with achondroplasia. No differences were observed in global spinal postures between the two groups. Conclusions: Spinal mobility appears to be more influenced by achondroplasia than global spinal postures in childhood. These results also highlight the importance of considering the musculoskeletal assessment of segmental spinal postures and rehabilitative interventions aimed at promoting spinal flexibility in children with achondroplasia.

2.
Acta Anaesthesiol Scand ; 68(5): 626-634, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38425207

RESUMO

BACKGROUND: High positive end-expiratory pressure (PEEP>10 cmH2O) is commonly used in mechanically ventilated hypoxemic patients with COVID-19. However, some epidemiological and physiological studies indirectly suggest that using a lower PEEP may primarily and beneficially decrease lung hyperinflation in this population. Herein we directly quantified the effect of decreasing PEEP from 15 to 10 cmH2O on lung hyperinflation and collapse in mechanically ventilated patients with COVID-19. METHODS: Twenty mechanically ventilated patients with COVID-19 underwent a lung computed tomography (CT) at PEEP of 15 and 10 cmH2O. The effect of decreasing PEEP on lung hyperinflation and collapse was directly quantified as the change in the over-aerated (density below -900 HU) and non-aerated (density above -100 HU) lung volumes. The net response to decreasing PEEP was computed as the sum of the change in those two compartments and expressed as the change in the "pathologic" lung volume. If the pathologic lung volume decreased (i.e., hyperinflation decreased more than collapse increased) when PEEP was decreased, the net response was considered positive; otherwise, it was considered negative. RESULTS: On average, the ratio of arterial tension to inspiratory fraction of oxygen (PaO2:FiO2) in the overall study population was 137 (119-162) mmHg. In 11 (55%) patients, the net response to decreasing PEEP was positive. Their over-aerated lung volume decreased by 159 (98-186) mL, while the non-aerated lung volume increased by only 58 (31-91) mL. In nine (45%) patients, the net response was negative. Their over-aerated lung volume decreased by 46 (18-72) mL, but their non-aerated lung volume increased by 107 (44-121) mL. CONCLUSION: In 20 patients with COVID-19 the net response to decreasing PEEP, as assessed with lung CT, was variable. In approximately half of them it was positive (and possibly beneficial), with a decrease in hyperinflation larger than the increase in collapse.


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , Choque , Humanos , Complacência Pulmonar/fisiologia , COVID-19/terapia , Pulmão/diagnóstico por imagem , Respiração com Pressão Positiva/métodos , Tomografia Computadorizada por Raios X
3.
iScience ; 27(3): 109262, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38433926

RESUMO

Micro-computed tomography derived functional biomarkers used in lung disease research can significantly complement end-stage histomorphometric measures while also allowing for longitudinal studies. However, no approach for visualizing lung dynamics across a full respiratory cycle has yet been described. Using bleomycin-induced lung fibrosis and the antifibrotic drug nintedanib as a test model, we implemented a four-dimensional (4D) micro-CT imaging approach consisting of 30 reconstructed volumes per respiratory cycle, coupled with deep-learning-assisted segmentation of lung volumes. 4D micro-CT provided an accurate description of inhalatory and exhalatory lung dynamics under resting conditions and revealed an inflammation-related obstructive pattern at day 7, followed by a restrictive pattern associated with fibrosis development at day 21. A milder restriction and fibrotic pathology resulted from nintedanib treatment. The similarity of 4D micro-CT data with those produced by diagnostic measurements, also points to its great potential as an exploratory tool for the discovery of clinically relevant therapeutic compounds.

4.
Int J Comput Assist Radiol Surg ; 19(4): 757-766, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386176

RESUMO

PURPOSE: Intracardiac transcatheter interventions allow for reducing trauma and hospitalization stays as compared to standard surgery. In the treatment of mitral regurgitation, the most widely adopted transcatheter approach consists in deploying a clip on the mitral valve leaflets by means of a catheter that is run through veins from a peripheral access to the left atrium. However, precise manipulation of the catheter from outside the body while copying with the path constraints imposed by the vessels remains challenging. METHODS: We proposed a path tracking control framework that provides adequate motion commands to the robotic steerable catheter for autonomous navigation through vascular lumens. The proposed work implements a catheter kinematic model featuring nonholonomic constraints. Relying on the real-time measurements from an electromagnetic sensor and a fiber Bragg grating sensor, a two-level feedback controller was designed to control the catheter. RESULTS: The proposed method was tested in a patient-specific vessel phantom. A median position error between the center line of the vessel and the catheter tip trajectory was found to be below 2 mm, with a maximum error below 3 mm. Statistical testing confirmed that the performance of the proposed method exhibited no significant difference in both free space and the contact region. CONCLUSION: The preliminary in vitro studies presented in this paper showed promising accuracy in navigating the catheter within the vessel. The proposed approach enables autonomous control of a steerable catheter for transcatheter cardiology interventions without the request of calibrating the intuitive parameters or acquiring a training dataset.


Assuntos
Cardiologia , Insuficiência da Valva Mitral , Robótica , Humanos , Cateteres , Valva Mitral
5.
J Hum Kinet ; 89: 5-18, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38053963

RESUMO

Fluency is a movement parameter combining smoothness and hesitation, and its objective measurement may be used to determine the effects of practice on sports performance. This study aimed to measure fluency in parkour, an acrobatic discipline comprising complex non-cyclical movements, which involves fluency as a critical aspect of performance. Inter-individual fluidity differences between advanced and novice athletes as well as intra-individual variations of fluency between different parts and subsequent repetitions of a path were addressed. Seventeen parkour participants were enrolled and divided into two groups based on their experience. We analysed signals captured from an inertial measurement unit fixed on the back of the pelvis of each participant during three consecutive repetitions of a specifically designed parkour routine under the guidance of video analysis. Two fluency parameters, namely smoothness and hesitation, were measured. Smoothness was calculated as the number of inflexions on the so-called jerk graph; hesitation was the percentage of the drop in the centre of mass velocity. Smoothness resulted in significantly lower values in advanced athletes (mean: 126.4; range: 36-192) than in beginners (mean: 179.37; range: 98-272) during one of the three motor activities (p = 0.02). A qualitative analysis of hesitation showed that beginner athletes tended to experience more prominent velocity drops and negative deflection than more advanced athletes. In conclusion, a system based on a video and an inertial measurement unit is a promising approach for quantification and the assessment of variability of fluency, and it is potentially beneficial to guide and evaluate the training process.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38083222

RESUMO

Wearable devices represent a non-invasive tool to monitor cardio-respiratory parameters. This paper presents a telemedicine platform constituted of four wireless units. Three wearable inertial measurement units monitor the respiratory-related excursions of the thorax and of the abdomen with respect to a reference unit (positioned on the lower back), through which respiratory rate and normalized tidal volume are extracted. The fourth unit is a reflectance wrist-worn pulse oximeter. To validate the system, 20 healthy volunteers (12 men) participated in a protocol designed to induce desaturation conditions and subsequent changes in the respiratory pattern by means of rebreathing. The results were evaluated against two different gold standards (SenTec for pulse oximetry and Cardiopulmonary Exercise Testing machine for all units) with Bland-Altman analyses. The resulting biases for the oxygen saturation comparison between the device to be validated and the SenTec and CPET systems are -0.90% and -2.68% respectively, with agreement intervals equal to [-6.37, 4.57] and [-9.00, 3.63]. Regarding the respiratory rate comparison with respect to the CPET system, the bias is -0.01 bpm with a [-11.36, 11.35] agreement interval.Clinical Relevance-This paper provides a validation of an integrated non-invasive wearable system for cardio-respiratory monitoring to be used outside of clinical settings and during the daily life of patients.


Assuntos
Dispositivos Eletrônicos Vestíveis , Masculino , Humanos , Monitorização Fisiológica , Oximetria , Frequência Cardíaca , Punho
7.
Digit Health ; 9: 20552076231218858, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38107981

RESUMO

Objective: The aim of the study was to develop an app to improve patients' adherence to therapy for osteoporosis and to test its usability. Methods: In Phase I, the app functions needed to improve medication adherence were identified through a focus group with six patients with osteoporosis and a joint interview with two bone specialists. The app prototype was then developed (Phase II) and refined after its feasibility testing (Phase III) for 13-25 days by eight patients. Finally, the app underwent usability testing (Phase IV) for 6 months by nine other patients. The mHealth App Usability Questionnaire (MAUQ) was used to collect the assessment of the app by the 17 patients. Results: The final version of the app provided information on osteoporosis, allowed patients to contact the bone specialist for an additional consultation, and generated a reminder for taking medications accompanied by feedback on adherence. The assessment of the app was positive but evaluations differed between the feasibility and usability testing, with the former displaying a significantly (p ≤ .05) better assessment across all MAUQ items. Conclusions: In this study, we tested an app for improving adherence to medical therapies in patients with osteoporosis. The usability testing revealed a lower "patient-centered" performance of the app as compared to that observed during the feasibility phase. Future developments of the study include increasing the testing cohort and adding a technical support during the usability testing.

8.
Front Digit Health ; 5: 1330189, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38152629

RESUMO

Step counting is among the fundamental features of wearable technology, as it grounds several uses of wearables in biomedical research and clinical care, is at the center of emerging public health interventions and recommendations, and is gaining increasing scientific and political importance. This paper provides a perspective of step counting in wearable technology, identifying some limitations to the ways in which wearable technology measures steps and indicating caution in current uses of step counting as a proxy for physical activity. Based on an overview of the current state of the art of technologies and approaches to step counting in digital wearable technologies, we discuss limitations that are methodological as well as epistemic and ethical-limitations to the use of step counting as a basis to build scientific knowledge on physical activity (epistemic limitations) as well as limitations to the accessibility and representativity of these tools (ethical limitations). As such, using step counting as a proxy for physical activity should be considered a form of reductionism. This is not per se problematic, but there is a need for critical appreciation and awareness of the limitations of reductionistic approaches. Perspective research should focus on holistic approaches for better representation of physical activity levels and inclusivity of different user populations.

9.
Sci Rep ; 13(1): 17753, 2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37852999

RESUMO

Obesity is frequently associated with breathing disorders. To investigate if and how the highest levels of obesity impact respiratory function, 17 subjects with obesity (median age: 49 years; BMI: 39.7 kg/m2, 8 females) and 10 normal-weighted subjects (49 years; 23.9 kg/m2, 5 females) were studied. The abdominal volume occupied 41% in the obese group, being higher (p < 0.001) than the normal-weighted group (31%), indicating accumulation of abdominal fat. Restrictive lung defect was present in 17% of subjects with obesity. At rest in the supine position, subjects with obesity breathed with higher minute ventilation (11.9 L/min) and lower ribcage contribution (5.7%) than normal weighted subjects (7.5 L/min, p = 0.001 and 31.1%, p = 0.003, respectively), thus indicating thoracic restriction. Otherwise healthy obesity might not be characterized by a systematic restrictive lung pattern. Despite this, another sign of restriction could be poor thoracic expansion at rest in the supine position, resulting in increased ventilation. Class 3 obesity made respiratory rate further increased. Opto-electronic plethysmography and its thoraco-abdominal analysis of awake breathing add viable and interesting information in subjects with obesity that were complementary to pulmonary function tests. In addition, OEP is able to localize the restrictive effect of obesity.


Assuntos
Parede Torácica , Feminino , Adulto , Humanos , Pessoa de Meia-Idade , Pulmão , Respiração , Obesidade , Caixa Torácica
10.
Eur J Prev Cardiol ; 30(Suppl 2): ii16-ii21, 2023 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819222

RESUMO

Heart failure (HF) is characterized by an increase in ventilatory response to exercise of multifactorial aetiology and by a dysregulation in the ventilatory control during sleep with the occurrence of both central and obstructive apnoeas. In this setting, the study of the ventilatory behaviour during exercise, by cardiopulmonary exercise testing, or during sleep, by complete polysomnography or simplified nocturnal cardiorespiratory monitoring, is of paramount importance because of its prognostic value and of the possible effects of sleep-disordered breathing on the progression of the disease. Moreover, several therapeutic interventions can significantly influence ventilatory control in HF. Also, rest daytime monitoring of cardiac, metabolic, and respiratory activities through specific wearable devices could provide useful information for HF management. The aim of the review is to summarize the main studies conducted at Centro Cardiologico Monzino on these topics.


Assuntos
Insuficiência Cardíaca , Consumo de Oxigênio , Humanos , Consumo de Oxigênio/fisiologia , Respiração , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Pulmão , Prognóstico , Teste de Esforço , Ventilação Pulmonar/fisiologia
11.
Respir Physiol Neurobiol ; 318: 104162, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37703923

RESUMO

The pathogenesis of hypoxemia during acute respiratory distress syndrome caused by SARS-CoV-2 infection (C-ARDS) is debated. Some observations led to hypothesize ventilation to perfusion mismatch, rather than anatomical shunt, as the main determinant of hypoxemia. In this observational study 24 C-ARDS patients were studied 1 (0-1) days after intubation. Patients underwent a CT scan analysis to estimate anatomical shunt and a clinical test to measure venous admixture at two fractions of inspired oxygen (FiO2), to eliminate oxygen-responsive mechanisms of hypoxemia (ventilation to perfusion mismatch and diffusion limitation). In 10 out of 24 patients venous admixture was higher than anatomical shunt both at clinical (≈50 %) and 100 % FiO2. These patients were ventilated with a higher PEEP and had lower amount of anatomical shunt compared with patients with venous admixture equal/lower than anatomical shunt. In a subset of C-ARDS patients early after endotracheal intubation, hypoxemia might be explained by an abnormally high perfusion of a relatively low anatomical shunt.

12.
Artigo em Inglês | MEDLINE | ID: mdl-37754597

RESUMO

The widespread use of digital technologies that can be worn on our bodies-wearables-is presented as a turning point for various areas of biomedical research and healthcare, such as stress. The ability to constantly measure these parameters, the perceived quality of measurement, and their individual and personal level frame wearable technology as a possibly crucial step in the direction of a more accurate and objective definition and measurement of stress for clinical, research, and personal purposes. In this paper, we discuss the hypothesis that the use of wearables for stress is also beneficial from an ethical viewpoint. We start by situating wearables in the context of existing methods and limitations of stress research. On this basis, we discuss the ethics of wearables for stress by applying ethical principles from bioethics (beneficence, non-maleficence, autonomy, justice), which allows us to identify ethical benefits as well as challenges in this context. As a result, we develop a more balanced view of the ethics of wearables for stress, which we use to present recommendations and indications with a focus on certification, accessibility, and inclusion. This article is, thus, a contribution towards ethically grounded wearable and digital health technology for stress.

13.
ERJ Open Res ; 9(4)2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37583963

RESUMO

It is a challenge to keep abreast of all the clinical and scientific advances in the field of respiratory medicine. This article contains an overview of the laboratory-based science, clinical trials and qualitative research that were presented during the 2022 European Respiratory Society International Congress within the sessions from the five groups of Assembly 1 (Respiratory Clinical Care and Physiology). Selected presentations are summarised from a wide range of topics: clinical problems, rehabilitation and chronic care, general practice and primary care, mobile/electronic health (m-health/e-health), clinical respiratory physiology, exercise and functional imaging.

14.
Ann Intensive Care ; 13(1): 60, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37405546

RESUMO

BACKGROUND: To develop and validate classifier models that could be used to identify patients with a high percentage of potentially recruitable lung from readily available clinical data and from single CT scan quantitative analysis at intensive care unit admission. 221 retrospectively enrolled mechanically ventilated, sedated and paralyzed patients with acute respiratory distress syndrome (ARDS) underwent a PEEP trial at 5 and 15 cmH2O of PEEP and two lung CT scans performed at 5 and 45 cmH2O of airway pressure. Lung recruitability was defined at first as percent change in not aerated tissue between 5 and 45 cmH2O (radiologically defined; recruiters: Δ45-5non-aerated tissue > 15%) and secondly as change in PaO2 between 5 and 15 cmH2O (gas exchange-defined; recruiters: Δ15-5PaO2 > 24 mmHg). Four machine learning (ML) algorithms were evaluated as classifiers of radiologically defined and gas exchange-defined lung recruiters using different models including different variables, separately or combined, of lung mechanics, gas exchange and CT data. RESULTS: ML algorithms based on CT scan data at 5 cmH2O classified radiologically defined lung recruiters with similar AUC as ML based on the combination of lung mechanics, gas exchange and CT data. ML algorithm based on CT scan data classified gas exchange-defined lung recruiters with the highest AUC. CONCLUSIONS: ML based on a single CT data at 5 cmH2O represented an easy-to-apply tool to classify ARDS patients in recruiters and non-recruiters according to both radiologically defined and gas exchange-defined lung recruitment within the first 48 h from the start of mechanical ventilation.

15.
Disabil Rehabil Assist Technol ; : 1-10, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37272556

RESUMO

PURPOSE: To investigate the acceptability and user experience of an in-hospital endurance training program based on the Virtual Park, a semi-immersive Virtual Reality (VR) system for patients with Chronic Obstructive Pulmonary Disease (COPD).Materials and methodsPatients performed 20 min of cycling two times/day for around ten days. The evaluation included adherence, exercise capacity, physical performance, and user experience. RESULTS: Fourteen patients (6 F/8 M; age = 71.29 ± 6.93 years) with mild/moderate COPD participated. The adherence rate was satisfying: 85.71% of patients attended the program without adverse events; the individual attendance rate (86.85% ± 27.43) was also high. The exercise capacity assessed before and after the training significantly improved in our group (6MWT pre-post: t(11)= -5.040, p < 0.05), as happens in standard PR programs. The physical performance metrics of each session indicate that all participants could sustain the proposed training protocol over the whole period. Patients judged the VR experience positively (User Experience Questionnaire = 1.84 ± 0.22) and were highly engaged in the activity for the whole period (Short Flow State Scale pre-post: 4.61 ± 0.27/4.40 ± 0.36). CONCLUSIONS: Our preliminary results open the possibility for further investigations on long-term motivation and clinical effectiveness of more immersive VR interventions for COPD.


The Virtual Park system is specifically designed for COPD, allows personalized endurance training in compliance with official clinical recommendations, while providing a semi-immersive virtual reality experience of a bicycle ride in a park.Patients reported a positive experience after two weeks of training with the Virtual Park cycling system; they were highly engaged in the activity for the whole period and across multiple sessions.

16.
Respir Res ; 24(1): 126, 2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37161569

RESUMO

Micro-computed tomography (µCT)-based imaging plays a key role in monitoring disease progression and response to candidate drugs in various animal models of human disease, but manual image processing is still highly time-consuming and prone to operator bias. Focusing on an established mouse model of bleomycin (BLM)-induced lung fibrosis we document, here, the ability of a fully automated deep-learning (DL)-based model to improve and speed-up lung segmentation and the precise measurement of morphological and functional biomarkers in both the whole lung and in individual lobes. µCT-DL whose results were overall highly consistent with those of more conventional, especially histological, analyses, allowed to cut down by approximately 45-fold the time required to analyze the entire dataset and to longitudinally follow fibrosis evolution and response to the human-use-approved drug Nintedanib, using both inspiratory and expiratory µCT. Particularly significant advantages of this µCT-DL approach, are: (i) its reduced experimental variability, due to the fact that each animal acts as its own control and the measured, operator bias-free biomarkers can be quantitatively compared across experiments; (ii) its ability to monitor longitudinally the spatial distribution of fibrotic lesions, thus eliminating potential confounding effects associated with the more severe fibrosis observed in the apical region of the left lung and the compensatory effects taking place in the right lung; (iii) the animal sparing afforded by its non-invasive nature and high reliability; and (iv) the fact that it can be integrated into different drug discovery pipelines with a substantial increase in both the speed and robustness of the evaluation of new candidate drugs. The µCT-DL approach thus lends itself as a powerful new tool for the precision preclinical monitoring of BLM-induced lung fibrosis and other disease models as well. Its ease of operation and use of standard imaging instrumentation make it easily transferable to other laboratories and to other experimental settings, including clinical diagnostic applications.


Assuntos
Aprendizado Profundo , Fibrose Pulmonar , Animais , Humanos , Camundongos , Fibrose Pulmonar/induzido quimicamente , Fibrose Pulmonar/diagnóstico por imagem , Fibrose Pulmonar/tratamento farmacológico , Microtomografia por Raio-X , Reprodutibilidade dos Testes , Bleomicina/toxicidade , Modelos Animais de Doenças
17.
Comput Methods Programs Biomed ; 238: 107621, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37247473

RESUMO

BACKGROUND AND OBJECTIVE: The Nine-Hole Peg Test (NHPT) is the most used test to assess hand dexterity in clinical practice and is considered the gold standard but only evaluates the time needed to complete the task. The aim of this work is to describe a graphic test on a smart tablet to assess in a quantitative as well qualitative way the dominant hand dexterity and to validate it in a cohort of neurological subjects and healthy controls. METHODS: The task consists in asking the subject to connect with a graphic line the start and the end point of a pre-defined path, with two different widths, in the most precise and fastest way possible. The path is constituted by a 'meander' and a 'spiral' part. The subjects perform the task on a smart tablet with a capacitive pen four times. The three parameters of interest considered at each trial are the execution time, length path, and number of interactions with the border. The app automatically computes these three parameters and stores the completed test files. The results of the digital graphic test are compared to the NHPT results. Healthy and pathological subjects are compared to each other, and performances obtained in different repetitions are compared to assess the learning effect in each population. RESULTS: 53 subjects with a definitive diagnosis of neurodegenerative/genetic neurological disorders (34 men, mean age 59.1 ± 16.1) and 78 healthy controls (33 men, mean age 42.5 ± 16.3) were recruited. Among the pathological subjects, 31 also performed the NHPT. The graphic test clearly distinguish between the two populations for all parameters of interest. Moreover, compared to the gold standard NHPT, time has a moderate positive correlation (r = 0.57, p ≤ 0.001), whereas interactions and length have a strong positive correlation (r = 0.81, p ≤ 0.001) and (r = 0.69, p ≤ 0.001), respectively. CONCLUSIONS: The proposed digital test can measure in an accurate, quantitative and qualitative way dominant hand disability and can result more informative with respect to the gold standard NHPT. In homogeneous cohort of subjects (for example affected by multiple sclerosis or Parkinson disease), the digital test can be used as an outcome measure in clinical trials as well as a tool for monitoring disease progression at the dominant hand level.


Assuntos
Esclerose Múltipla , Doença de Parkinson , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Avaliação de Resultados em Cuidados de Saúde , Progressão da Doença , Mãos
18.
J Med Internet Res ; 25: e42815, 2023 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-37052980

RESUMO

BACKGROUND: Preoperative assessment is crucial to prevent the risk of complications of surgical operations and is usually focused on functional capacity. The increasing availability of wearable devices (smartwatches, trackers, rings, etc) can provide less intrusive assessment methods, reduce costs, and improve accuracy. OBJECTIVE: The aim of this study was to present and evaluate the possibility of using commercial smartwatch data, such as those retrieved from the Fitbit Inspire 2 device, to assess functional capacity before elective surgery and correlate such data with the current gold standard measure, the 6-Minute Walk Test (6MWT) distance. METHODS: During the hospital visit, patients were evaluated in terms of functional capacity using the 6MWT. Patients were asked to wear the Fitbit Inspire 2 for 7 days (with flexibility of -2 to +2 days) after the hospital visit, before their surgical operation. Resting heart rate and daily steps data were retrieved directly from the smartwatch. Feature engineering techniques allowed the extraction of heart rate over steps (HROS) and a modified version of Non-Exercise Testing Cardiorespiratory Fitness. All measures were correlated with 6MWT. RESULTS: In total, 31 patients were enrolled in the study (n=22, 71% men; n=9, 29% women; mean age 76.06, SD 4.75 years). Data were collected between June 2021 and May 2022. The parameter that correlated best with the 6MWT was the Non-Exercise Testing Cardiorespiratory Fitness index (r=0.68; P<.001). The average resting heart rate over the whole acquisition period for each participant had r=-0.39 (P=.03), even if some patients did not wear the device at night. The correlation of the 6MWT distance with the HROS evaluated at 1% quantile was significant, with Pearson coefficient of -0.39 (P=.04). Fitbit step count had a fair correlation of 0.59 with 6MWT (P<.001). CONCLUSIONS: Our study is a promising starting point for the adoption of wearable technology in the evaluation of functional capacity of patients, which was strongly correlated with the gold standard. The study also identified limitations in the availability of metrics, variability of devices, accuracy and quality of data, and accessibility as crucial areas of focus for future studies.


Assuntos
Monitores de Aptidão Física , Dispositivos Eletrônicos Vestíveis , Masculino , Humanos , Feminino , Idoso , Frequência Cardíaca/fisiologia , Monitorização Fisiológica , Caminhada
19.
Ann Biomed Eng ; 51(7): 1535-1546, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37061594

RESUMO

This paper describes a cancer detection procedure based on customised electrical impedance spectroscopy (EIS) in breast cancer surgical samples and an analysis of its outcomes. A tissue analyser was developed to inject a low-amplitude alternating current with penetrating electrodes into breast specimens along a broad spectrum of frequencies. Experimental measurements were carried out on more than one hundred excised breast cancer specimens, with the goal of discriminating between the tumour and surrounding non-neoplastic tissue. The probe was inserted in different locations immediately after surgical excision in order to measure tissue impedance (modulus and phase). Electrical impedance varied significantly between neoplastic and surrounding non-neoplastic tissues, with a low standard deviation among the different measurements, confirming good reproducibility. Tumours could be discriminated from non-neoplastic tissues according to their impedance modulus value for high frequencies and phase value for low frequencies. Impedance also varied significantly in both non-neoplastic and tumour tissues depending on the patient's age and tumour characteristics, such as size and histological sub-type. EIS is able to discriminate between healthy tissue and cancer. Future developments of this technology could be exploited for intraoperative real-time evaluation of the transition zone between cancer and normal tissues.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico , Espectroscopia Dielétrica , Reprodutibilidade dos Testes , Impedância Elétrica , Fígado
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...